{"id":2974,"date":"2024-09-02T16:27:28","date_gmt":"2024-09-02T08:27:28","guid":{"rendered":"https:\/\/www.oilfieldsequipments.com\/?p=2974"},"modified":"2024-09-02T16:27:30","modified_gmt":"2024-09-02T08:27:30","slug":"f-500-f-800-f-1000-f-1300-f-1500-f-1600-triplex-drilling-mud-pump-for-drilling","status":"publish","type":"post","link":"https:\/\/www.oilfieldsequipments.com\/?p=2974","title":{"rendered":"F-500\/F-800\/F-1000\/F-1300\/F-1500\/F-1600 Triplex Drilling Mud Pump for Drilling"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">F-500\/F-800\/F-1000\/F-1300\/F-1500\/F-1600 Triplex Drilling Mud Pump for Drilling<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F-1300&nbsp;mud pump can be used to circulate the drilling fluids, clean the bottom of the hole, carry the drill cuttings out of the hole, cool, clean and lubricate the drill bit, and support the well in drilling operation in the oil and gas field, it is a kind of horizontal medium-speed triplex single acting piston pump. It mainly suits to Rig 32-45&nbsp;with drilling depth 3200m to 4500m.<strong>Technical Data<\/strong><br>-Mud Pump Type: &nbsp;&nbsp;Triplex Single Acting<br>-Rated Power: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1300 HP\/969 KW<br>-Rated Stroke: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;120 SPM<br>-Liner Stroke: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12 &#8221; \/305 mm<br>-Gear Ratio: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.206:1<br>-Suction Inlet: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12&#8221; \/305 mm<br>-Discharge Inlet: &nbsp;&nbsp;&nbsp;5 1\/8 in Flange 5000 psi<br>-Gear Type: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Herringbone<br>-Lubrication; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Forced&amp;Splash<br>-Valve Pot: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;API-7#<br>-Overall Size: &nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;Length: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4617 mm &nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;Width: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3260 mm<br>Height: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2600 mm<br>-Weight(approx.): &nbsp;&nbsp;24572 kg<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong><br>-Max. Pressure: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;5075 PSI\/35 Mpa<br>-Max. Flow: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;737GPM\/46.54 L\/S with 180mm Liner<br>-Max. Stroke Length: &nbsp;12&#8221; \/305 mm<br>-Max. Liner Size: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7&#8221; \/180 mm<br>-Liner Size:<br>&nbsp;&nbsp;&nbsp;Inch: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7&#8243;, 6 3\/4&#8243;, 6 1\/4&#8243;, 6&#8243;, 5 1\/2&#8243;, 5&#8243;<br>&nbsp;&nbsp;&nbsp;mm: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;180mm, 170mm, 160mm, 150mm, 140mm, 130mm<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F-1600&nbsp;mud pump can be used to circulate the drilling fluids, clean the bottom of the hole, carry the drill cuttings out of the hole, cool, clean and lubricate the drill bit, and support the well in drilling operation in the oil and gas field, it is a kind of horizontal medium-speed triplex single acting piston pump. It mainly suits to Rig 45-80 with drilling depth 4500m to 8000m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Technical Data<\/strong><br>-Mud Pump Type: &nbsp;&nbsp;Triplex Single Acting<br>-Rated Power: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1600 HP\/1193 KW<br>-Rated Stroke: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;120 SPM<br>-Liner Stroke: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12 in\/305 mm<br>-Gear Ratio: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.206:1<br>-Suction Inlet: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;12 in\/305 mm<br>-Discharge Inlet: &nbsp;&nbsp;&nbsp;5 1\/8 in Flange 5000 psi<br>-Gear Type: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Herringbone<br>-Lubrication; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Forced&amp;Splash<br>-Valve Pot: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;API-7#<br>-Overall Size: &nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;Length: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4615 mm &nbsp;&nbsp;<br>&nbsp;&nbsp;&nbsp;&nbsp;Width: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3276 mm<br>Height: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2688 mm<br>-Weight(approx.): &nbsp;&nbsp;24791 kg<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Note:<\/strong><br>-Max. Pressure: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;5075 PSI\/35 Mpa<br>-Max. Flow: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;737GPM\/46.54 L\/S with 180mm Liner<br>-Max. Stroke Length: &nbsp;12 in\/305 mm<br>-Max. Liner Size: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7 in\/180 mm<br>-Liner Size:<br>&nbsp;&nbsp;&nbsp;Inch: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7&#8243;, 6 3\/4&#8243;, 6 1\/2&#8243;, 6 1\/4&#8243;, 6&#8243;, 5 1\/2&#8243;, 5&#8243;,4 1\/2&#8243;<br>&nbsp;&nbsp;&nbsp;mm: &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;180mm, 170mm, 160mm, 150mm, 140mm, 130mm<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Pump <\/strong><strong>Speed<\/strong><br><strong>(SPM)<\/strong><\/td><td colspan=\"6\"><strong>Liner Size and Pressure Rating(Mpa) \/(PSI)<\/strong><\/td><\/tr><tr><td><\/td><td>7<\/td><td>6-3\/4<\/td><td>6-1\/4<\/td><td>6<\/td><td>5-1\/2<\/td><td>5<\/td><\/tr><tr><td><\/td><td>24.19<br>3508<\/td><td>25.46<br>3692<\/td><td>29.66<br>4300<\/td><td>32.16<br>4663<\/td><td>34.5<br>5000<\/td><td>35<br>5075<\/td><\/tr><tr><td><\/td><td colspan=\"6\"><strong>Displacement (L\/S) \/(GPM)<\/strong><\/td><\/tr><tr><td>120<\/td><td>45.41<br>720<\/td><td>42.23<br>669<\/td><td>36.20<br>574<\/td><td>33.36<br>529<\/td><td>28.04<br>444<\/td><td>23.17<br>367<\/td><\/tr><tr><td>110<\/td><td>41.63<br>660<\/td><td>38.71<br>614<\/td><td>33.19<br>526<\/td><td>30.58<br>485<\/td><td>25.70<br>407<\/td><td>21.24<br>337<\/td><\/tr><tr><td>100<\/td><td>37.84<br>600<\/td><td>35.19<br>558<\/td><td>30.17<br>478<\/td><td>27.80<br>441<\/td><td>23.36<br>370<\/td><td>19.31<br>306<\/td><\/tr><tr><td>90<\/td><td>34.06<br>540<\/td><td>31.67<br>502<\/td><td>27.15<br>430<\/td><td>25.02<br>397<\/td><td>21.03<br>333<\/td><td>17.38<br>275<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" src=\"blob:https:\/\/www.oilfieldsequipments.com\/1b6cead1-0df9-4d3b-83fd-13ea0356e2a3\" width=\"25\" height=\"25\"><img loading=\"lazy\" decoding=\"async\" src=\"blob:https:\/\/www.oilfieldsequipments.com\/57d03239-f6ab-4fa6-a47c-fd666cb58450\" width=\"25\" height=\"25\"><img loading=\"lazy\" decoding=\"async\" src=\"blob:https:\/\/www.oilfieldsequipments.com\/4ad6c8bc-8c90-4506-9064-a2877927a4a1\" width=\"15\" height=\"15\"><img loading=\"lazy\" decoding=\"async\" src=\"blob:https:\/\/www.oilfieldsequipments.com\/247c0496-7598-4c37-9aac-54c4f7fe64fd\" width=\"15\" height=\"15\"><strong>Note:<\/strong>1. Based on 100% volumetric efficiency and 90% mechanical efficiency.<br>&nbsp;2. Recommend stokes and input powers are under continuous operation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"577\" height=\"438\" src=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-1.jpg\" alt=\"\" class=\"wp-image-2975\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-1.jpg 577w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-1-300x228.jpg 300w\" sizes=\"auto, (max-width: 577px) 100vw, 577px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-1024x768.jpg\" alt=\"\" class=\"wp-image-2976\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-1024x768.jpg 1024w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-300x225.jpg 300w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-768x576.jpg 768w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-1536x1152.jpg 1536w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2-600x450.jpg 600w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/09\/F-500-F-800-F-1000-F-1300-F-1600-Triplex-Drilling-Mud-Pump-for-Drilling-2.jpg 1614w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>F-500\/F-800\/F-1000\/F-1300\/F-1500\/F-1600 Triplex Dr [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2975,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2974"}],"version-history":[{"count":1,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2974\/revisions"}],"predecessor-version":[{"id":2977,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2974\/revisions\/2977"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/media\/2975"}],"wp:attachment":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}