{"id":2891,"date":"2024-08-02T16:49:07","date_gmt":"2024-08-02T08:49:07","guid":{"rendered":"https:\/\/www.oilfieldsequipments.com\/?p=2891"},"modified":"2024-08-02T16:49:08","modified_gmt":"2024-08-02T08:49:08","slug":"rexroth-valve-r431003805-8p-1s-p55556-3-ia480-aventics-r431003805-control-air-valve","status":"publish","type":"post","link":"https:\/\/www.oilfieldsequipments.com\/?p=2891","title":{"rendered":"Rexroth Valve R431003805\/8p-1s\/P55556-3\/Ia480 Aventics R431003805 Control Air Valve"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Rexroth Valve R431003805\/8p-1s\/P55556-3\/Ia480 Aventics R431003805 Control Air Valve<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Description of Models<\/strong><br><strong>The H-2-X Type Controlair Valves <\/strong>are handle operated<br>4-way, exhausted center, pressure control<br>valves.<br>The typical unit contains two directional control 3-way<br>side valves and a pressure graduating portion that is<br>arranged to increase, decrease or maintain air pressure<br>to a separate delivery line. In neutral position,<br>both 3-way side valves exhaust both delivery lines. A<br>movement of 10 degrees either side of center position<br>opens the appropriate side valve and directs<br>pressure to the indicated outlet port. Continued<br>movement past 10 degrees up to full travel, or 46<br>degrees either side of neutral continues to actuate<br>the pressure graduating portion to deliver a graduated<br>pressure according to the valve of the control<br>spring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Models<\/strong><br>There are six models with similar valve functions, but<br>different handle operating characteristics.<br><strong>HD-2-X Controlair Valve <\/strong>-Handle is spring returned<br>to neutral position from all positions in the handle<br>travel. Some special models exist. See notes on<br>Identity schedule on page 7.<br><strong>HD-2-LX Controlair Valve <\/strong>&#8211; Handle is spring returned<br>to neutral position from all positions except at<br>the maximum pressure setting on both sides of center.<br>The handle is held in both extreme positions by<br>a mechanical detent.<br><strong>HD-2-FX Controlair Valve <\/strong>&#8211; Handle is equipped with<br>a friction brake that will hold the handle in any position<br>selected in the handle travel.<br><strong>HD-2-XS Controlair Valve <\/strong>&#8211; Handle detents in both<br>maximum pressure positions. The handle is spring<br>returned to neutral position from all other positions in<br>the handle travel. Graduated pressure to port (8) is<br>only delivered in one direction of the handle movement.<br><strong>HD-2-FXR Controlair Valve <\/strong>&#8211; Handle function is<br>similar to the HD-2-FX Valve. The difference is the<br>two directional valves are <em>supplied <\/em>instead of being<br><em>exhausted <\/em>when the handle is in the neutral position,<br><strong>HD-2-LS Controlair Valve<\/strong>&#8211; Handle holds in full travel,<br>neutral and detent positions.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-1024x768.jpg\" alt=\"\" class=\"wp-image-2892\" style=\"width:600px;height:auto\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-1024x768.jpg 1024w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-300x225.jpg 300w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-768x576.jpg 768w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-1536x1152.jpg 1536w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1-600x450.jpg 600w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-1.jpg 1706w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-1024x768.jpg\" alt=\"\" class=\"wp-image-2893\" style=\"width:591px;height:auto\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-1024x768.jpg 1024w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-300x225.jpg 300w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-768x576.jpg 768w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-1536x1152.jpg 1536w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2-600x450.jpg 600w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-2.jpg 1706w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3-768x1024.jpg\" alt=\"\" class=\"wp-image-2894\" style=\"width:607px;height:auto\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3-768x1024.jpg 768w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3-225x300.jpg 225w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3-1152x1536.jpg 1152w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3-600x800.jpg 600w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/08\/Rexroth-Valve-R431003805-8p-1s-P55556-3-Ia480-Aventics-R431003805-Control-Air-Valve-3.jpg 1280w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Rexroth Valve R431003805\/8p-1s\/P55556-3\/Ia480 Aven [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2892,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2891","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2891"}],"version-history":[{"count":2,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2891\/revisions"}],"predecessor-version":[{"id":3512,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2891\/revisions\/3512"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/media\/2892"}],"wp:attachment":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2891"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2891"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}