{"id":2365,"date":"2024-04-01T09:57:50","date_gmt":"2024-04-01T01:57:50","guid":{"rendered":"https:\/\/www.oilfieldsequipments.com\/?p=2365"},"modified":"2024-07-19T17:09:39","modified_gmt":"2024-07-19T09:09:39","slug":"controlair-valve-r431003824-hc-2-lx","status":"publish","type":"post","link":"https:\/\/www.oilfieldsequipments.com\/?p=2365","title":{"rendered":"Controlair Valve R431003824\/HC-2-LX"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td colspan=\"2\">Series H-Controlair\u00ae<br>Version HC-2, OUT port \u2013 delivers increasing pressure when lever is moved clockwise from<br>\u201cOff\u201d (facing lever side of valve).<br>Qn = 900 l\/min<br>Actuating element Lever<br>Internal thread<br>Poppet valve<br>HC-2-X HC-2-FX HC-2-LX<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Version Poppet valve<br>Working pressure min.\/max. 0.1 \u2026 14 bar<br>Adjustment range min.\/max. See table below<br>Ambient temperature min.\/max. -40 \u2026 70 \u00b0C<br>Medium temperature min.\/max. -40 \u2026 70 \u00b0C<br>Medium Compressed air<br>Nominal flow Qn 900 l\/min<br>Hysteresis 0.1 bar<br>Weight 2.3 kg<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"http:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840.jpg\" alt=\"\" class=\"wp-image-2362\" style=\"width:253px;height:auto\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840.jpg 400w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840-300x300.jpg 300w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840-150x150.jpg 150w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840-230x230.jpg 230w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/AVENTICS-R431002840-160x160.jpg 160w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>The HC-2 CONTROLAIR Valve is a lever operated, pressure regulating, 4-way directional valve. It consists of two 3-way directional valves, and a 3-way pressure regulating portion. The regulating portion furnishes the inlet air for the directional valves. Each directional valve has its own OUT port.<\/p>\n\n\n\n<p>Initial lever movement from &#8220;Off&#8221; position selects the OUT port to be activated, Further lever movement in the same direction controls the outlet pressure of the air at that port. The opposite OUT port remains connected to atmosphere.<\/p>\n\n\n\n<p>These valves are used to control two clutches, two brakes, a clutch and a brake, two single acting cylinders or a double acting cylinder. In fact, wherever it is desired to control, with one lever, the flow and pressure in one or the other of two separate air lines.<\/p>\n\n\n\n<p>PIPE CONNECTIONS<br>Port 1-OUT graduated pressure when lever is moved clockwise from &#8220;Off&#8221; (facing lever side of valve).<br>Port 2-IN pressure.<br>Port 3-OUT graduated pressure when lever is moved counterclockwise from &#8220;Off&#8221;.<\/p>\n\n\n\n<p>Lever automatically returns to &#8220;Off&#8221; position when released from any position except maximum pressure position<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"294\" height=\"365\" src=\"http:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/1711702955712.png\" alt=\"\" class=\"wp-image-2363\" srcset=\"https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/1711702955712.png 294w, https:\/\/www.oilfieldsequipments.com\/wp-content\/uploads\/2024\/03\/1711702955712-242x300.png 242w\" sizes=\"auto, (max-width: 294px) 100vw, 294px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Series H-Controlair\u00aeVersion HC-2, OUT port \u2013 deliv [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2362,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2365","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2365","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2365"}],"version-history":[{"count":2,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2365\/revisions"}],"predecessor-version":[{"id":5561,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/posts\/2365\/revisions\/5561"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=\/wp\/v2\/media\/2362"}],"wp:attachment":[{"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2365"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2365"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oilfieldsequipments.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2365"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}